200-500 MHz, DPM Plug-In Elements (D Series)
200-500 MHz, DPM Elements
DPM D Series, Elements are designed to be used with the 5010 Series, Digital Power Sensors. Using familiar form element design, the DPM Element can accurately measure true average power.
Element Guide |
|||
FWD Power | RFL Power | FWD Element | RFL Element |
125 mW to 5 W 1.25 W to 50 WW |
12.5 mW to 500 W 125 mW to 5 W |
DPM-5D DPM-50D |
DPM-.5D DPM-5D |
Specifications
- Frequency Range: 200-500 MHz
- True Average Power Accuracy: +15 to +35° (±5% of Reading)
-10 to +15° & +35 to +50° (±7% of Reading)
Typical system accuracy when used with 5000 Series, Power Sensors - Directivity: 30dB (typ) | 25dB (min)
- Peak-to-Average Ratio: 10 dB (min)
- Pulse-Width Parameters: >100 MHz: 800ns (min)
26-99 MHz: 1.5 micro sec (min)
2-25 MHz: 15 micro sec (min) - Pulse Rep Rate Peak: 15 pps (min)
- Dynamic Range: 16dB